The short version of retention time fits in a sentence. The long version — which is the one that helps — is below.
This page was last updated on 2026-05-24 and is reviewed periodically as new material appears.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample. A pump moves a liquid mobile phase through a column packed with a solid stationary phase. Compounds interact differently with both phases and travel at different rates, leaving the column at distinct retention times. A detector records these arrivals as peaks on a chromatogram. The resulting pattern supports identification and quantification of substances in mixtures. Modern instruments use high pressure to force solvent through small particles, which improves speed and resolution compared with older low-pressure liquid chromatography methods.
Separation in HPLC depends on the chemistry of the stationary phase, the composition of the mobile phase, and the physical properties of the column. Reverse-phase separations use a nonpolar stationary phase and a polar mobile phase, and they are common for many organic compounds. Ion-exchange, size-exclusion, and normal-phase modes serve other classes of analytes. Gradient elution changes solvent strength over time, while isocratic elution holds it constant. Flow rate, temperature, particle size, and column length all influence peak shape and resolution. Detection may use ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry, depending on the analyte and the required sensitivity.
Reversed-phase chromatography dominates modern HPLC testing, using a nonpolar stationary phase such as chemically bonded octadecyl groups and a polar mobile phase of water mixed with organic solvent. Analytes partition between the mobile and stationary phases according to hydrophobicity. Gradient elution changes the mobile phase composition over time to separate compounds with a wide range of retention. Isocratic elution keeps the composition constant and is simpler for routine assays. Column temperature, pH, and flow rate influence selectivity, peak shape, and retention time, so these parameters are controlled during a validated method.
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. A diode array detector records full spectra across a wavelength range, which helps identify co-eluting peaks. Mass spectrometry provides mass-to-charge ratios and can confirm molecular identity at low concentrations. The choice of detector depends on analyte structure, required sensitivity, and whether quantitation or identification is the goal. No single detector works for every compound, and method development often compares responses before selecting one.
High-performance liquid chromatography is an analytical technique that separates components of a liquid sample by passing it through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in interaction with the stationary phase cause analytes to migrate at different rates. Detectors record elution as peaks, and a data system converts signals into a chromatogram. The method is suited to compounds that dissolve in a liquid and are not volatile enough for gas chromatography.
| Property | Value | Notes |
|---|---|---|
| Common abbreviation | HPLC | High-performance liquid chromatography |
| Separation basis | Differential partitioning | Between liquid mobile phase and solid stationary phase |
| Common mode | Reverse phase | Nonpolar column, polar mobile phase |
| Typical detector | UV-Vis absorbance | Widely used for compounds with chromophores |
| Typical column particle size | 2–5 µm | Smaller particles can improve resolution |
Documentation and traceability are central to regulated HPLC testing. Records typically include instrument logs, column history, mobile-phase preparation, sample preparation, injection sequences, raw chromatograms, and audit trails. Electronic systems may require user access controls, time-stamped changes, and backup procedures. Training records show that analysts are qualified for assigned methods. Audits and inspections check whether written procedures match actual practice and whether deviations are documented. These controls support reproducibility and allow results to be reconstructed if questions arise later.
Method validation establishes that an HPLC procedure is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, robustness, and solution stability. Accuracy reflects closeness to a reference value, while precision reflects agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from matrix components. Validation is documented through protocols and reports, and the required extent depends on the method's use and regulatory context.
Routine quality control uses system suitability, blank injections, check standards, and control samples to detect drift or contamination. System suitability criteria may specify minimum resolution, maximum tailing factor, and a permitted range for repeated injections. Blank injections reveal carryover or solvent contamination, while check standards confirm calibration accuracy over a batch. Control samples with known analyte levels can show whether results remain within statistical limits. When a control result falls outside limits, the analyst investigates the cause and may invalidate affected results before repeating the batch.
Method validation evaluates accuracy, precision, specificity, linearity, range, detection limit, quantitation limit, and robustness. Regulatory guidance for pharmaceuticals, foods, and environmental testing defines expected documentation and acceptance criteria. Verification confirms that a validated method works in a specific laboratory with its own instruments and reagents. Calibration curves use reference standards with known purity and traceability, while measurement uncertainty is estimated from validation data, control charts, and collaborative studies. The scope of validation depends on the method's intended use.
Routine quality control monitors retention time shifts, baseline noise, system pressure, and peak shape. Trends can reveal column aging, mobile phase preparation errors, detector drift, or sample degradation. Corrective actions may include replacing the column, preparing fresh mobile phase, or recalibrating the detector. Stability testing often uses HPLC to measure parent compound loss and degradation product formation. Open questions remain about how accelerated stability results extrapolate to long-term storage under varied conditions.
Quality control samples are inserted at intervals to monitor accuracy and precision throughout a batch. Blank samples detect contamination, while spiked samples assess recovery from the sample matrix. Calibration standards establish the relationship between detector response and concentration, and control samples are prepared independently from them whenever possible. Laboratories also participate in proficiency testing and maintain audit trails, instrument logs, and reagent records. Ongoing review of control charts can reveal trends before they cause out-of-specification results.
Method validation demonstrates that an HPLC procedure is suitable for its intended purpose. Common validation parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantification, and robustness. Accuracy reflects agreement with a reference value, while precision describes repeatability under defined conditions. Specificity shows whether the method can measure the analyte in the presence of impurities or matrix components. Validation documents are reviewed before a method is used for routine testing or regulatory submissions.
Routine quality control includes blanks, duplicates, spiked samples, and certified reference materials. Calibration curves are prepared with standards at several concentrations, and the detector response is checked for linearity. Carryover, column aging, mobile phase evaporation, and temperature drift can shift retention times or peak areas. Maintenance such as replacing seals, filters, and columns helps prevent failures. Records of injections, integration, and deviations support traceability. Audits may request raw data and instrument logs for each batch.
Developing an HPLC test begins with defining the analytes, matrix, and required reporting limits. Chemists select a separation mode, column chemistry, mobile phase composition, flow rate, and detection wavelength or mass transition. Experiments then adjust these variables to achieve adequate retention, resolution, and peak shape. System suitability tests confirm that the instrument and method perform consistently before sample analysis. Without suitable resolution, quantitative results may be unreliable. Preliminary runs often use scouting gradients to locate retention windows.
An insulin pump delivers insulin subcutaneously. The insulin pump body itself can also contain the algorithm used in an AID system, or it can connect via Bluetooth with a separate mobile device (such as a phone) to send data and receive commands to adjust insulin delivery. Algorithm The algorithm for each AID system differs. In commercial systems (see below), little is known about the details of how the control algorithm works. In open source systems, the code and algorithm are openly available. In general, all algorithms do the same basic functionality of taking in CGM data and based on predicted glucose level's and the user's personal settings (for basal rates, insulin sensitivity, and carbohydrate ratio, for example) then recommends insulin dosing to help bring or maintain glucose levels in target range. Depending on the system, users may have the ability to adjust the target for the system, and may have different settings to ask the system to give more or less insulin in general.
In 1955, a USAF surgeon who advised the US Surgeon General wrote an article on how to make cars safer for those riding in it. Aside from the usual safety features, such as seat belts and padded dashboards, bumper shocks were introduced. In 1956, Ford tried unsuccessfully to interest Americans in purchasing safer cars with their Lifeguard safety package. (Its attempt nevertheless earns Ford Motor Trend's "Car of the Year" award for 1956.) In 1958, the United Nations established the World Forum for Harmonization of Vehicle Regulations, an international standards body advancing auto safety. Many of the most life saving safety innovations, like seat belts and roll cage construction were brought to market under its auspices. That same year, Volvo engineer Nils Bohlin invented and patented the three-point lap and shoulder seat belt, which became standard equipment on all Volvo cars in 1959. Over the next several decades, three-point safety belts were gradually mandated in all vehicles by regulators throughout the industrialised world. In 1959, American Motors Corporation offered the first optional head rests for the front seat. Also in 1959, the Cadillac Cyclone concept by Harley Earl had "a radar-based crash-avoidance system" located on the nose cones of the vehicle that would make audible and visual signals to the driver if there were obstacles in the vehicle's path.
Amino acids are the building blocks of protein and together they form the protein requirements in formula needed for growth and development. The amino acids are in the simplest form, making it easy for the body to process and digest. Amino acid-based formula may be considered hypoallergenic since it does not contain peptides that may trigger an immune response. Because infants and children have different nutritional needs, amino acid-based formulas are typically formulated either for infants 0–1 years of age or for children 1–10 years of age. Amino acid-based formulas may be used for those with cow's milk or soy protein allergy. However, most infants who suffer from food allergy respond well to extensively hydrolysed formulas, and only few of those with the most severe form of the illness require the use of amino acid-based formulas. It may also be used for other medical conditions requiring an amino acid-based diet, such as short bowel syndrome, and for transition from parenteral to enteral nutrition. Milk allergy Food allergy
APEKTx1 is a highly selective blocker of the voltage-gated potassium channel Kv1.1 with no effect on other tested potassium channels (Kv1.2, Kv1.3, Kv1.4, Kv1.5, Kv1.6, Shaker IR, Kv2.1, Kv3.1, Kv4.2 and Kv4.3). APEKTx1 selectively blocks Kv1.1 channels with an IC50 value of 0.9 nM, which makes it between a 700 to 3000 times more potent inhibitor than the two known sea anemone peptides targeted against Kv channels (kalicludines and SHTX II). APEKTx1 is thought to interact with Kv1.1 through the aliphatic residue alanine (A352), an acidic residue glutamate (E353), and an aromatic residue tyrosine (Y379), as a mutation in these sites causes a loss in affinity of the toxin for Kv1.1. These residues are located in the H5-loop between the S5 and S6 domains and are part of the channel’s pore. In addition, APEKTx1 acts as a potent trypsin inhibitor (Kd= 124 nM), probably a competitive one. However, trypsin inhibition is more potent (as it has a higher affinity) in BPTI, which can be explained by the presence of Phe13 and Pro19 in APEKTx1, causing an unfavorable interaction.
Sources: en.wikipedia.org
GOT1/cAST, the cytosolic isoenzyme derives mainly from red blood cells and heart. GOT2/mAST, the mitochondrial isoenzyme is present predominantly in liver. These isoenzymes are thought to have evolved from a common ancestral AST via gene duplication, and they share a sequence homology of approximately 45%. AST has also been found in a number of microorganisms, including E. coli, H. mediterranei, and T. thermophilus. In E. coli, the enzyme is encoded by the aspCgene and has also been shown to exhibit the activity of an aromatic-amino-acid transaminase (EC 2.6.1.57).
These weight reduction treatments include the injection of HCG, a drug which has not been approved by the Food and Drug Administration as safe and effective in the treatment of obesity or weight control. There is no substantial evidence that HCG increases weight loss beyond that resulting from caloric restriction, that it causes a more attractive or "normal" distribution of fat, or that it decreases the hunger and discomfort associated with calorie-restrictive diets. There was a resurgence of interest in the "HCG diet" following promotion by Kevin Trudeau, who was banned from making HCG diet weight-loss claims by the U.S. Federal Trade Commission in 2008, and eventually jailed over such claims. A 1976 study in the American Journal of Clinical Nutrition concluded that HCG is not more effective as a weight-loss aid than dietary restriction alone. A 1995 meta analysis found that studies supporting HCG for weight loss were of poor methodological quality and concluded that "there is no scientific evidence that HCG is effective in the treatment of obesity; it does not bring about weight-loss or fat-redistribution, nor does it reduce hunger or induce a feeling of well-being". On November 15, 2016, the American Medical Association (AMA) passed policy that "The use of human chorionic gonadotropin (HCG) for weight loss is inappropriate."
Lactation suppression Hyperprolactinemia Adjunctive therapy of prolactin-producing pituitary gland tumors (prolactinomas); Monotherapy of Parkinson's disease in the early phase; Combination therapy, together with levodopa and a decarboxylase inhibitor such as carbidopa, in progressive-phase Parkinson's disease; In some countries also: ablactation and dysfunctions associated with hyperprolactinemia (amenorrhea, oligomenorrhea, anovulation, nonpuerperal mastitis and galactorrhea); Treatment of uterine fibroids. Adjunctive therapy of acromegaly: Cabergoline has low efficacy in suppressing growth hormone levels and is highly efficient in suppressing hyperprolactinemia, which is present in 20–30% of acromegaly cases. Growth hormone and prolactin are similar structurally and have similar effects in many target tissues; therefore, targeting prolactin may help symptoms when growth hormone secretion cannot be sufficiently controlled by other methods. Cabergoline is frequently used as a first-line agent in the management of prolactinomas due to its higher affinity for D2 receptor sites, less severe side effects, and more convenient dosing schedule than the older bromocriptine, though in pregnancy bromocriptine is often still chosen since there is less data on safety in pregnancy for cabergoline.
Aviation Safety Network Established in 1996. The ASN Safety Database contains descriptions of over 15800 airliner, military and corporate jet aircraft accidents/incidents since 1921. Bureau of Aircraft Accidents Archives Established in 2000. The B3A contains descriptions of over 22,000 airliner, military and corporate jet aircraft accidents since 1918. National Transportation Safety Board Aviation Accident Synopses – by month Aviation Statistics Statistical and geospatial analysis of general aviation accidents. Aviation Accidents App Access the NTSB Aviation Accidents Database and Final Reports from all over the world on your mobile device Aviation Accidents Map Explore an interactive map showcasing airplane crash sites Air Crash Map | Interactive Aviation Accident Database
A sequence space is usually laid out as a grid. For protein sequence spaces, each residue in the protein is represented by a dimension with 20 possible positions along that axis corresponding to the possible amino acids. Hence there are 400 possible dipeptides arranged in a 20x20 space but that expands to 10130 for even a small protein of 100 amino acids arranged in a space with 100 dimensions. Although such overwhelming multidimensionality cannot be visualised or represented diagrammatically, it provides a useful abstract model to think about the range of proteins and evolution from one sequence to another. These highly multidimensional spaces can be compressed to 2 or 3 dimensions using principal component analysis. A fitness landscape is simply a sequence space with an extra vertical axis of fitness added for each sequence.
Sources: en.wikipedia.org
HPLC testing measures the presence and amount of one or more compounds in a liquid sample. It separates mixture components and records detector responses as peaks, which are compared with reference standards. Results are usually reported as concentrations or relative percentages.
Retention time is the interval between sample injection and the detector response for a given compound. It depends on the compound's interactions with the stationary and mobile phases under set conditions. Matching a retention time to a standard supports tentative identification but is not always unique.
HPLC alone can separate unknown compounds and provide retention times, but it often cannot identify them with certainty. Coupling HPLC to mass spectrometry gives mass information that improves identification. Confirmation usually requires comparison with reference standards or complementary techniques.
HPLC testing separates and quantifies components in a liquid sample. It is used to check identity, purity, concentration, or stability. The technique works best for compounds that dissolve and are not easily vaporized.